REVO NX 130
World’sFastest OCT
- Weight::
- Brand ::
- No.::
World’sFastest OCT
New OCT standard - All functionality In One device.
Once again Revo NX goes beyond the limits of standard OCT. With its new scanning speed, our Revo NX 130 enables a full functionality scanning from the retina to the cornea. It brings benefits by combining the potential of several devices. With REVO you can measure, quantify, calculate and track changes from the cornea to the retina over time with just one OCT device.
i Tracking™
iTracking™ technology compensates involuntary eye movements and blinks. When OCT scan is used each anatomical region is acquired twice automatically. The system immediately creates an artifactfree MC examination using the Motion Correction TechnologyTM. The elimination of eye movement and blinking artifacts ensures the highest resolution of Angio OCT images without patient inconvenience. Clear OCTA data set allows easier interpret retina vasculature condition
AI denoise
Improved tomogram quality powered by Artificial Intelligence. Advanced AI algorithms enhance the quality of a single tomogram to the level of an averaged tomogram obtained through multiple scanning.
RAW Tomogram | AiDenoise Tomogram |
Full range
New Extended DepthTM Retina imaging, based on our Full Range technology, provides scans of increased depth for reliable and convenient observation of challenging cases. With scans presenting plenty of depth, this new imaging mode is perfect for diagnosing even highly myopic patients.
RETINA
Single 3D Retina examination is enough to perform both Retina and Glaucoma analysis based on retinal scans. Software automatically recognize 8 retina layers. Thus allowing a more precise diagnosis and mapping any changes in the patient’s retina condition.
Single | Both |
Comparison | Progression |
Progression Morphology | Progression Quantification |
Advance Retina & ONH | ONH Single |
Ganglion Both | Ganglion Progression |
ONH Both | ONH Progression |
Closing angle | Anterior Radial Single View Cornea |
Full Range Anterior Chamber single view | |
* Images curtesy of Edward Wylęgała, MD, PhD |
VF sensitivity results (24-2/30-2 or 10-2)
Total and Pattern Deviation probability graphs for VF results
Reliability and Global indices for VF results
Combined map of Structure & Function
Ganglion cell analysis (GCL+IPL or NFL+GCL+IPL)
ONH and NFL analysis including charts and comparison tables
NFL Asymmetry Plot
The S&F report compares in a natural way the anatomical relationship between VF and RNFL/Ganglion maps.
Structure & Function |
SINGLE PAGE REPORT
S+F provides a quick and comprehensive single page report for glaucoma management.
ANTERIOR CHAMBER
Additional adapter provided with the device allows the user to perform the imaging of the anterior segment. Now you can display the whole anterior segment or focus on a small area to bring out the details of the image.
Anterior Chamber exam with a fast view of the whole Anterior Chamber make the evaluation of gonioscopy situation and the verification of cataract lens easier and faster.
Full Range Anterior Chamber | Full Range Anterior Chamber with Lens |
Full Range Lens | |
ANTERIOR SEGMENT
For standard examinations no additional lens is required. Additional adapter provided with the device allows to make wide scans of anterior segment.
Cornea single | Cornea both |
Cornea Comparison | Cornea Progression |
NETWORKING
A proficient networking solution increases productivity and an enhanced patient experience. It allows you to view and manipulate multiple examinations from review stations in your practice. Effortlessly helping to facilitate patient education by allowing you to interactively show examination results to patients. Every practice will have differing requirements which we can provide by tailoring a bespoke service. There is no additional charge for the server module.
DICOM
Store, exchange, and transmit results through DICOM gateway to the hospital network.
OCT ANGIOGRAPHY is optional software module to purchase
This optional software module allows visualization of the retinal microvasculature. Angiography SOCT is a non-invasive, dye-free technique providing 3D image of retinal blood circulation.
Standard Single View | Detailed Single View |
Both View | |
Comparison View | Progression View |
ANGIO ANALYISIS METHODS
QUANTIFICATION
The quantification tool provides quantification of the vasculature in the whole analyzed area together with values in specific zones and sectors. Thanks to the heat map of the analyzed vasculature the evaluation of vascular structure conditions is much faster. The choice of the quantification method increases the sensitivity of analyses for specific deseases.
Available quantification methods:
Vessel Area Density - it is defined as the total area of perfused vasculature per unit area in a region of measurement.
Skeleton Area Density - it is defined as the total area of skeletonized vasculature per unit area in a region of measurement.
Quantification is available for a specific layer in Angio OCT exam:
Retina: Superficial Plexus and Deep Plexus
Disc: RPC - Radial Peripapillary Capillary
Skeleton Density Map | Vessel Density Map |
ANGIO-ANALYTICAL TOOLS
FAZ – Foveal Avascular Zone measurements enable the quantification and monitoring of changes in Superficial and Deep vascular layers. The FAZ tool is also available for narrow and wide scans.
FAZ Area [mm2] Perimeter [mm] Circularity |
VFA – Vascular Flow Area allows the user to examine the pathologically affected area and to precisely measure the area covered by vascularization.
The simple and easy area measurement can be performed on a predefined or user-selected vascular layer.
Area [mm2] Flow Area [mm2] |
NFA – Non Flow Area measurement tool makes it possible to quantify the Non Flow Area on the OCT Angio examination. It provides the sum of all marked areas.
Non Flow Area [mm2] |
ANGIO MOSAIC
The Angiography mosaic delivers high-detailed images over large field of the retina.
Advanced tab provides: view of any vascular layers, enface view of vascular layers, depth coded and thickness map. Mosaic modes: 10x6 mm, 12x5 mm, 7x7 mm, 10x10 mm and Manual (up to 12 images).
CNV case | BRVO case |
BIOMETRY OCT is optional software module to purchase
B-OCT™ innovative method of using the posterior OCT device to measure ocular structure along eye axis .
OCT Biometry provides complete set of Biometry parameters: Axial Length AL, Central Cornea Thickness CCT, Anterior Chamber Depth ACD, Lens Thickness LT.
Result review | Analysis window |
Visually verify your measurement
All measurement calipers are shown on the all boundaries OCT image provided by REVO. Now, you can visually verify and correct what structure of the eye has been measured.
IOL CALCULATOR
IOL formulas allow the user to calculate IOL implant parameters. Our systems now support the latest IOL data base standard IOLCon.org so that you can always keep your library up-to-date.
TOPOGRAPHY OCT is optional software module to purchase
T-OCT™ is a pioneering way to provide detailed corneal Curvature maps by using posterior dedicated OCT. Ante-rior, Posterior surface and Corneal Thickness allow to provide the True Net Curvature information. With Net power, the precise understading of the patient’s corneal condition comes easily and is free of errors associated with modelling of posterior surface of the cornea. SOCT T-OCT module provides Axial maps, Tangential maps, Total Power map, Height maps, Epithelium and Corneal thickness maps.
Corneal topography module clearly shows the changes in the cornea on the difference map view. Customize your
Topography module provides:
Full featured Corneal mapping of Anterior, Posterior and Real
Precise Astigmatism Display Option (SimK: Anterior, Posterior, Real, Meridian and Emi-Meridian ø 3, 5, 7 mm zones
KERATOCONUS SCREENING
Easly detect and classified keratoconus with Keratoconus classifier. Classification based on KPI, SAI, DSI, OSI and CSI. In the early stages of kera-toconus the results can be complemented by Epithelium and Pachymatery maps.
Normal | Astigmatysm | Keratoconus |
COMPARE THE EXAMS
Comprehensive software features a range of selectable views: Single, Both. See details on standard Singe view and easly see corneal asymmetry on the Both view.
The follow-up feature in to the T-OCT™ module, allows fully compare the changes in the corneal topography over time for:
LASIK undergone patients
Keratoconus patients
The contact lens wearers
Single | Both |
Comparison | Progression |
Technology | Spectral Domain OCT |
Scanning speed | 130 000 A-scan/sec |
Light Source | SLED, Wavelength 850nm |
Bandwidth | 50 nm half bandwidth |
Axial resolution | ~2.6 μm digital, 5 μm in tissue |
Transverse Resolution | 12 μm, typical 18 μm |
Overall scan depth | 2.8 mm / ~6 mm in Full Range mode |
Scan range | Posterior 5 mm to 15 mm, Angio 3 mm to 9 mm, Anterior 3 mm to 18 mm |
Scan types | 3D, Angio, Full Range Radial, Full Range B-scan, Radial (HD), B-scan (HD), Raster (HD), Cross (HD), TOPO, AL, ACD |
Fundus image | Live Fundus Reconstruction |
Alignment method | Fully automatic, Automatic, Manual |
Retina analysis | Retina thickness, Inner Retinal thickness, Outer Retinal thickness, RNFL+GCL+IPL thickness, GCL+IPL thickness, RNFL thickness, RPE deformation, MZ/EZ-RPE thickness |
Angiography OCT an optional software module to purchase Angiography mosaic | Vitreous, Retina, Choroid, Superficial Plexus, RPCP, Deep Plexus, Outer Retina, Choriocapilaries, Depth Coded, SVC, DVC, ICP, DCP, Custom, Enface, FAZ, VFA, NFA, Quantification: Vessel Area Density, Skeleton Area Density, Thickness map Acquistion method: Auto, Manual Mosaic modes: 7x7 mm, 10x6 mm, 10x10 mm, 12x5 mm, manual up to 12 images |
Glaucoma analysis | RNFL, ONH morphology, DDLS, OU and Hemisphere asymmetry, Ganglion analysis as RNFL+GCL+IP and GCL+IPL, Structure + Functionvia connection with PTS software version 3.4 or higher |
Anterior | Pachymetry, Epithelium map, Stroma map, AIOP, Angle Assessment, AOD 500/750, TISA 500/750 |
Biometry OCT an optional software module to purchase | AL, CCT, ACD, LT, P, WTW IOL Formulas: Hoffer Q, Holladay I, Haigis, Theoretical T, Regression II |
Corneal Topography Map an optional software module to purchase | Axial [Anterior, Posterior], Refractive Power [Kerato, Anterior, Posterior, Total], Net Map, Axial True Net, Equivalent Keratometer, Elevation [Anterior, Posterior], Height, KPI (Keratoconus Prediction Index) |
Connectivity | DICOM Storage SCU, DICOM MWL SCU, CMDL, Networking |
Anterior Wide Scan | Anterior Chamber Radial, Anterior Chamber B-scan, Angle to Angle view (Adapter required) Wide Cornea |
Min. pupil size | 2.4 mm |
Focus adjustment range | -25D to +25D |
Dimensions (WxDxH) | 479 x 367 × 493 mm |
Weight | 29 kg |
Fixation target | OLED display (The target shape and position can be changed), External fixation arm |
Power supply | 110-230 V, 60/50 Hz |
Power consumption | 90 - 110 VA |