Optopol

REVO NX 130

World’sFastest OCT

  • Weight::
  • Brand ::
  • No.::

World’s
Fastest OCT

New OCT standard - All functionality In One device.

Once  again Revo NX goes beyond the limits of standard OCT. With its new scanning  speed, our Revo NX 130 enables a full functionality scanning from the retina to  the cornea. It brings benefits by combining the potential of several devices.  With REVO you can measure, quantify, calculate and track changes from the cornea  to the retina over time with just one OCT device.

i  Tracking™
iTracking™ technology compensates involuntary eye  movements and blinks. When OCT scan is used each anatomical region is acquired  twice automatically. The system immediately creates an artifactfree MC  examination using the Motion Correction TechnologyTM. The elimination of eye  movement and blinking artifacts ensures the highest resolution of Angio OCT  images without patient inconvenience. Clear OCTA data set allows easier  interpret retina vasculature condition

AI denoise
Improved tomogram quality powered by Artificial  Intelligence. Advanced AI algorithms enhance the quality of a single tomogram to  the level of an averaged tomogram obtained through multiple scanning.

RAW Tomogram
AiDenoise Tomogram

Full range
New Extended DepthTM Retina imaging,  based on our Full Range technology, provides scans of increased depth for  reliable and convenient observation of challenging cases. With scans presenting  plenty of depth, this new imaging mode is perfect for diagnosing even highly  myopic patients.

RETINA
Single 3D Retina examination is enough to perform  both Retina and Glaucoma analysis based on retinal scans. Software automatically  recognize 8  retina layers. Thus allowing a more precise diagnosis and mapping  any changes in the patient’s retina condition.

Single
Both
Comparison
Progression
FOLLOW UP
High density of standard 3D scan allows to  precisely track the disease progress. Operator can analyze changes is  morphology,  quantified progression maps or evaluate the progression  trends.

Progression MorphologyProgression Quantification
FOLLOW UP Progression Morphology	FOLLOW UP Progression Quantification
Precise registration
The software can track 3D scans and  register them to the OCT baseline exam by recognizing patterns in the shape of  blood vessels. Active tracking and post-processing point-to-point registration  allows the user to precisely see and track the changes in retina morphology in  Comparison and Progression analysis.


COMPARISON
Comparison  view allows in easy and convince way to review results from two visits. The view  is available for most of the scan programs.


GLAUCOMA
Comprehensive  glaucoma analytical tools for quantification of the Nerve Fiber Layer, Ganglion  layer and Optic Head with DDLS allow for the precise diagnosis and monitoring of  glaucoma over time.
With the golden standard 14 optic nerve parameters and a  new Rim to Disc and Rim Absence the description of ONH condition is quick and  precise.
Advanced view which provides combined information from Retina and  Disc scan to integrate details of the Ganglion cells, RNFL, ONH in a wide field  perspective for comprehensive analysis.

Advance Retina & ONH

ONH Single
GLAUCOMA Advance Retina & ONH GLAUCOMA ONH Single

Asymmetry  Analysis of Ganglion layers between hemi-spheres and between eyes allows easier  identification and detection of glaucoma in early stages and in non-typical  patients.

Ganglion Both

Ganglion Progression
GLAUCOMA Ganglion Both GLAUCOMA Ganglion Progression

Implemented  the DDLS  - Disc Damage Likelihood Scale which use 3 separate classification for  small, average and large discs. It supports the practitioners in a quick and  precise evaluation of the patient’s glaucomatous disc damages.

ONH Both

ONH Progression
GLAUCOMA ONH Both GLAUCOMA ONH Progression

COMPLET  YOUR GLAUCOMA REPORT
To eliminate common problem with the understanding of  the patient’s IOP pachymetry module provides IOP Correction value.  With the  implemented Adjusted IOP formula you can quickly and precisely understand the  measured IOP value. 
As the Pachymetry and Anterior Chamber Angle  Verification require no additional attachments, the predefined Glaucoma  protocol, which consists of Retina, Disc and Anterior scans, can be done  automatically to reduce patient chair time.


Closing angle

Anterior Radial Single View Cornea
Closing angle Anterior single view
Full Range Anterior Chamber single view

  * Images curtesy of Edward Wylęgała, MD, PhD
COMPREHENSIVE GLAUCOMA SOLUTION

STRUCTURE &  FUNCTION - Combined OCT and VF results analysis

Invaluable  combination of information about the functional quality of vision with  comprehensive data on retinal Ganglion Cells, RNFL and Optic Nerve Head for both  eyes on a single report page. The S&F report contains the following:

  • VF sensitivity results (24-2/30-2 or 10-2)

  • Total and Pattern Deviation probability graphs for VF results

  • Reliability and Global indices for VF results

  • Combined map of Structure & Function

  • Ganglion cell analysis (GCL+IPL or NFL+GCL+IPL)

  • ONH and NFL analysis including charts and comparison tables

  • NFL Asymmetry Plot

The S&F report compares in a natural way  the anatomical relationship between VF and RNFL/Ganglion maps.

Structure & Function
STRUCTURE & FUNCTION - Combined OCT and VF results analysis

SINGLE  PAGE REPORT
S+F provides a quick and comprehensive single page  report for glaucoma management.

ANTERIOR  CHAMBER
Additional adapter provided with the device allows the user  to perform the imaging of the anterior segment. Now you can display the whole  anterior segment or focus on a small area to bring out the details of the  image.
Anterior Chamber exam with a fast view of the whole Anterior Chamber  make the evaluation of gonioscopy situation and the verification of cataract  lens easier and faster.

Full Range Anterior ChamberFull Range Anterior Chamber with Lens
Full Range Lens


ANTERIOR SEGMENT
For  standard examinations no additional lens is required.  Additional adapter  provided with the device allows to make wide scans of anterior segment.


Cornea single

Cornea both
ANTERIOR Cornea single ANTERIOR Cornea both
Cornea ComparisonCornea Progression
Anterior Cornea ComparisonAnterior Cornea Progression


NETWORKING
A  proficient networking solution increases productivity and an enhanced patient  experience. It allows you to view and manipulate multiple examinations from  review stations in your practice. Effortlessly helping to facilitate patient  education by allowing you to interactively show examination results to patients.  Every practice will have differing requirements which we can provide by  tailoring a bespoke service. There is no additional charge for the server  module.

DICOM
Store, exchange, and transmit results  through DICOM gateway to the hospital network.

OCT ANGIOGRAPHY  is optional software module to purchase
This optional software  module allows visualization of the retinal microvasculature. Angiography SOCT is  a non-invasive, dye-free technique providing 3D image of retinal blood  circulation.

Software allows to observe, track and compare changes in the  microvasculature of the retina in both eyes.
Standard Single ViewDetailed Single View
OCT Angiography Standard Single View	OCT Angiography Detailed Single View
Both View
OCT Angiography Both View
Comparison ViewProgression View
OCT Angiography Comparison ViewOCT Angiography Progression View


ANGIO  ANALYISIS METHODS

QUANTIFICATION
The  quantification tool provides quantification of the vasculature in the whole  analyzed area together with values in specific zones and sectors. Thanks to the  heat map of the analyzed vasculature the evaluation of vascular structure  conditions is much faster. The choice of the quantification method increases the  sensitivity of analyses for specific deseases.

Available quantification  methods:

  • Vessel Area Density - it is defined as the total area of perfused  vasculature per unit area in a region of measurement.

  • Skeleton Area Density - it is defined as the total area of skeletonized  vasculature per unit area in a region of measurement.

Quantification is  available for a specific layer in Angio OCT exam:

  • Retina: Superficial Plexus and Deep Plexus

  • Disc: RPC - Radial Peripapillary Capillary

Quantification Skeleton Density Map Quantification Vessel Density Map
Skeleton Density MapVessel Density  Map


ANGIO-ANALYTICAL TOOLS
FAZ  – Foveal Avascular Zone measurements enable the quantification and monitoring of  changes in Superficial and Deep vascular layers. The FAZ tool is also available  for narrow and wide scans.

OCT Angiography FAZ – Foveal Avascular Zone OCT Angiography FAZ – Foveal Avascular Zone

FAZ Area [mm2]
Perimeter  [mm]
Circularity


VFA – Vascular Flow Area allows  the user to examine the pathologically affected area and to precisely measure  the area covered by vascularization.
The simple and easy area measurement can  be performed on a predefined or user-selected vascular layer.

OCT Angiography VFA – Vascular Flow Area OCT Angiography VFA – Vascular Flow Area

Area [mm2]
Flow Area  [mm2]


NFA – Non Flow Area measurement  tool makes it possible to quantify the Non Flow Area on the OCT Angio  examination. It provides the sum of all marked areas.

OCT Angiography NFA OCT Angiography NFA

Non Flow Area  [mm2]


ANGIO  MOSAIC
The Angiography mosaic delivers high-detailed images over  large field of the retina.
Advanced tab provides: view of any vascular  layers, enface view of vascular layers, depth coded and thickness map. Mosaic  modes: 10x6 mm, 12x5 mm, 7x7 mm, 10x10 mm and Manual (up to 12 images).

Mosaic modes: 10x10 mm
Mosaic modes: 7x7 mm
Mosaic modes: 10x6 mm
Manual (up to 12 images)
Mosaic modes: 12x5 mm
Mosaic modes: 12x5 mm - RPC Enface view
Mosaic modes: 12x5 mm -
NFL Thickness map
Mosaic modes: 12x5 mm -
Retina Thickness map

CNV caseBRVO case



BIOMETRY OCT is  optional software module to purchase
B-OCT™ innovative method of  using the  posterior OCT device to measure ocular structure along eye axis  .
OCT Biometry provides complete set of Biometry parameters: Axial Length  AL, Central Cornea Thickness  CCT, Anterior Chamber Depth  ACD, Lens Thickness  LT.


Result review

Analysis window

Visually  verify your measurement
All measurement calipers are shown on the all  boundaries OCT image provided by REVO. Now, you can visually verify and correct  what structure of the eye has been measured.

IOL  CALCULATOR
IOL formulas allow the user to calculate IOL implant  parameters. Our systems now support the latest IOL data base standard IOLCon.org  so that you can always keep your library up-to-date.


TOPOGRAPHY  OCT is optional software module to purchase
T-OCT™ is a pioneering  way to provide detailed corneal Curvature maps by using posterior dedicated OCT.  Ante-rior, Posterior  surface and Corneal Thickness allow to provide the  True  Net Curvature information. With Net power, the precise understading of the  patient’s corneal condition comes easily and is free of errors associated with  modelling of posterior surface of the cornea.  SOCT T-OCT module provides Axial  maps, Tangential maps, Total Power map, Height maps, Epithelium and Corneal  thickness maps.
Corneal topography module clearly shows the changes in the  cornea on the difference map view. Customize your
Topography module provides:

  • Full featured Corneal mapping of Anterior, Posterior and Real

  • Precise Astigmatism Display Option (SimK: Anterior, Posterior, Real,  Meridian and Emi-Meridian ø 3, 5, 7 mm zones

KERATOCONUS  SCREENING
Easly detect and classified keratoconus with Keratoconus  classifier. Classification based on KPI, SAI, DSI, OSI and CSI. In the early  stages of kera-toconus the results can be complemented by Epithelium and  Pachymatery maps.


Normal

Astigmatysm

Keratoconus
KERATOCONUS SCREENING KERATOCONUS SCREENING KERATOCONUS SCREENING


COMPARE  THE EXAMS
Comprehensive software features  a range of selectable views:  Single, Both. See details on standard Singe view and easly see corneal asymmetry  on the Both view.
The follow-up feature in to the T-OCT™ module, allows fully  compare the changes in the corneal topography over time for:

  • LASIK undergone patients

  • Keratoconus patients

  • The contact lens wearers

SingleBoth
TOPOGRAPHY OCT SINGLE TOPOGRAPHY OCT BOTH
ComparisonProgression
TOPOGRAPHY OCT COMPARISONTOPOGRAPHY OCT PROGRESSION

CLINICAL  IMAGES

ENHANCE TOMOGRAMS - 2 µm Ultra High (Digital)  Resolution


CHOROID  VISUALIZATION


CLINICAL  IMAGES




ANGIOGRAPHY


PDR,  Angio Mosaic mode:  10x10 mm
PDR,  Angio Mosaic mode 10x10 mm
*Images  courtesy of Bartosz L. Sikorski MD, PhD

CORNEA  SCAN

Wide  cornea scan, Descemet’s membrane detachment (DMD) and iridocorneal  adhesions

Wide cornea scan, Descemet’s membrane detachment (DMD) and iridocorneal adhesions
*  Images courtesy of Prof. Edward Wylęgała MD,  PhD

ANTERIOR

Anterior scan,  Cornea Guttata with corneal scaring
Anterior scan, Cornea Guttata with corneal scaring

*  Images courtesy of Prof. Edward Wylęgała MD, PhD

ANGLE TO  ANGLE ANALYSIS

Angle to Angle  scan, narrow angles
Angle to Angle scan, narrow angles
*Image  courtesy of Bartosz L. Sikorski MD, PhD



Tech specs
TechnologySpectral Domain OCT
Scanning speed130 000 A-scan/sec
Light SourceSLED, Wavelength 850nm
Bandwidth50 nm half bandwidth
Axial resolution~2.6 μm digital, 5 μm in tissue
Transverse Resolution12 μm, typical 18 μm
Overall scan depth2.8 mm / ~6 mm in Full Range mode
Scan rangePosterior 5 mm to 15 mm, Angio 3 mm to 9 mm, Anterior 3 mm to 18  mm
Scan types3D, Angio, Full Range Radial, Full Range B-scan, Radial (HD), B-scan (HD),  Raster (HD), Cross (HD), TOPO, AL, ACD
Fundus imageLive Fundus Reconstruction
Alignment methodFully automatic, Automatic, Manual
Retina analysisRetina thickness, Inner Retinal thickness, Outer Retinal thickness,  RNFL+GCL+IPL thickness, GCL+IPL thickness, RNFL thickness,
RPE deformation,  MZ/EZ-RPE thickness
Angiography OCT
an optional software module to  purchase


Angiography mosaic
Vitreous, Retina, Choroid, Superficial Plexus, RPCP, Deep Plexus, Outer  Retina, Choriocapilaries, Depth Coded, SVC, DVC, ICP, DCP, Custom, Enface, FAZ,  VFA, NFA, Quantification: Vessel Area Density, Skeleton Area Density, Thickness  map

Acquistion method: Auto, Manual
Mosaic modes: 7x7 mm, 10x6 mm,  10x10 mm, 12x5 mm, manual up to 12 images
Glaucoma analysisRNFL, ONH morphology, DDLS, OU and Hemisphere asymmetry, Ganglion analysis  as RNFL+GCL+IP and GCL+IPL,
Structure + Functionvia connection with PTS  software version 3.4 or higher
AnteriorPachymetry, Epithelium map, Stroma map, AIOP, Angle Assessment, AOD 500/750,  TISA 500/750
Biometry OCT
an optional software module to  purchase
AL, CCT, ACD, LT, P, WTW
IOL Formulas: Hoffer Q, Holladay I, Haigis,  Theoretical T, Regression II
Corneal Topography Map
an optional software module  to purchase
Axial [Anterior, Posterior], Refractive Power [Kerato, Anterior, Posterior,  Total], Net Map, Axial True Net, Equivalent Keratometer, Elevation [Anterior,  Posterior], Height, KPI (Keratoconus Prediction Index)
ConnectivityDICOM Storage SCU, DICOM MWL SCU, CMDL, Networking
Anterior Wide ScanAnterior Chamber Radial, Anterior Chamber B-scan,  Angle to Angle view  (Adapter required)
Wide Cornea
Min.  pupil size2.4 mm
Focus adjustment range-25D to +25D
Dimensions (WxDxH)479 x 367 × 493 mm
Weight29 kg
Fixation targetOLED display (The target shape and position can be changed),
External  fixation arm
Power supply110-230 V,  60/50 Hz
Power consumption90 - 110 VA